The CardioNS E2 is a high-quality and compact 12-channel ECG device designed for flexible use. It captures leads I, II, III, aVR, aVL, aVF and V1 to V6 and operates with complex and modern algorithms. These allow for reliable detection, identification and marking of anomalies, while simultaneously providing a real-time view of the heart's electrical activity.
Thanks to its plug-and-play functionality, no drivers or batteries are required, ensuring quick installation and setup. The CardioNS E2 is compatible with mobile devices and tablets. The free CardioNS app can be downloaded from the Google Play Store.
Equipped with a USB port, the ECG device provides a stable connection for data transfer. It also boasts excellent accuracy and low power consumption. After capturing an ECG, you can generate reports on sinus rhythm, tachycardia, 2nd-degree AV block, atrial fibrillation and arrhythmia in PDF format.
The CardioNS app allows for personalised visualisation of ECG signals, including customisation of colours and the number of signals. After capturing the resting ECG, the user can immediately review the results on a mobile device or print them as required.
| Dimensions | Basic Information |
|---|---|
| Width: 64.3 mm Depth: 22 mm Height: 50 mm Weight: 50 g |
ADC Resolution: 24 Bit Voltage: 5V/3.3V Power Consumption: 0.5 W Number of Channels: 12 (twelve) Sampling Rate: 100 Hz – 1066 Hz Input Range: ±5 mV |
| Processing | Patient Data |
| Purpose: Recording, displaying, interpreting, streaming, and printing ECG signals | Name, Date of Birth, Gender, Blood Pressure, Height, Weight, Status (Diabetes, Smoking, Alcohol, Hyperlipidaemia, Positive Family History, Medications, Pacemaker), Occupation, Address, Phone, Email |
| Recording Time | Filters |
| 1 to 60 minutes | Low-pass Filter: 25 Hz, 40 Hz, 65 Hz, 80 Hz, 100 Hz High-pass Filter: 0.05 Hz, 0.067 Hz, 0.4 Hz, 0.5 Hz, 0.67 Hz, 1 Hz Notch Filter: 50 or 60 Hz Digital Filter |
| Lead Display | Electrode Placement Detection |
| Standard (I, II, III), Unipolar (aVR, aVL, aVF), External (I, II, III, aVR, aVL, aVF), Precordial (V1-V6) | Pacemaker Detection: between 2 mV and 250 mV, Duration between 0.1 – 2.0 ms |
| Data Management | Protection Class |
| Report retrieval via the CardioNS application Secure print output via the internal network, direct .pdf storage on a local device Worklist integration for CSV |
Medical Device Category: Class IIa Applied Parts: CF RF Emissions (CISPR 11): Group 1, Class B Degree of Protection: IP22 |
| Applied Standards | Operating Conditions |
| ISO 15223-1:2016, EN ISO 15223-1:2016, EN 1041:2008/A1:2013, EN ISO 14971:2012, IEC 62366-1:2015, IEC 60601-1:2005+A1:2015 | Temperature: 5° to 40°C Relative Humidity: up to 90% (limited condensation) Air Pressure: 700 to 1060 hPa |
| Technical Requirements for the CardioNS Operating System | Operating System: Android OS 7.0 or higher Processor: Octa-Core CPU at 1.95 GHz per core RAM: 3 GB (minimum) Storage Space: Recommended 200 MB Connectivity: Wi-Fi 802.11b/g/n |