Built for trade pros. Copeland ZR three-phase scrolls are the go-to replacement compressors for Australian commercial A/C and light-med refrigeration using R22 or R407C. They’re proven tough on rooftops, quiet in plant rooms, and efficient where it counts — so you’re back off the ladder faster, with fewer call-backs. Fair dinkum.
Licensed HVAC & refrigeration techs, service contractors, and apprentices needing a dependable 3-phase scroll for packaged A/C, commercial splits, rooftops, heat pumps and rack retrofits
When you’re up on a roof in 40-degree heat, you want a compressor that just slots in and gets the job done. The ZR series gives you predictable performance on legacy R22 systems and R407C retrofits, with a POE charge that plays nicely across these gases. Last week in Brisbane we swapped a tired unit on a small office rooftop — wired, brazed, nitrogen tested, evacuated, and live within the hour. Client happy, crew back on the road. Too easy.
Shopping around? You can compare a popular model like ZR160KCE-TFD-522 for current pricing and lead times.
On first start, confirm correct rotation: suction pressure should drop and discharge should rise within seconds. If not, swap two supply phases or fit a phase monitor. It’ll save a return visit — and your Saturday. She’ll be right after that.
Quick reference for common 3-phase models. Always verify with the model datasheet before ordering.
| Model | Phase / Voltage | Refrigerant | Displacement (m³/h) | Weight | Notes |
|---|---|---|---|---|---|
| ZR61KCE-TFD-522 | 3φ 380–420 V 50 Hz | R22 / R407C | ≈14.3 | – | Compact rooftop & small commercial A/C. |
| ZR72KCE-TFD-522 | 3φ 380–420 V 50 Hz | R22 / R407C | – | ≈30.5 kg | Low sound power; packaged A/C & multi-split. |
| ZR81KCE-TFD-522 | 3φ 380–420 V 50 Hz | R22 / R407C | – | – | High-capacity commercial duty. |
| ZR160KCE-TFD-522 | 3φ 380–420 V 50 Hz | R22 / R407C | – | – | Popular replacement — see live pricing. Open model page. |
| ZR190KCE-TFD-522 | 3φ 380–420 V 50 Hz | R22 / R407C | – | – | Large rooftop/plant — verify stub sizes before ordering. |
Specs above are excerpted from Copeland model sheets and distributor listings; confirm final selection against the OEM datasheet for your exact operating envelope.
Usually, yes — the ZR series supports R22 and R407C. Make sure you address oil, charge, and expansion device sizing per the datasheet, and follow Australian refrigerant-handling rules. See federal guidance.
Highly recommended. Incorrect phase rotation means “running” but not pumping. Verify rotation at first start and add a monitor on sensitive sites to prevent reverse-phase restarts.
No — ZR is for legacy R22/R407C duty. For R410A, spec a Copeland ZP series scroll.
All HVAC Shop products are backed by the manufacturer’s warranty (minimum 12 months). Returns accepted within 30 days for unused items in original packaging. Read Shipping & Returns.
Working coastal Sydney rooftops or steamy Brisbane plant rooms? Salt air and heat cycles are brutal. Keep brazes clean, nitrogen-purge, then evacuate properly — you’ll avoid acid burnouts and keep the site manager off your back. No worries. Here’s a quick vacuum set-up refresher.
3-phase variant for small commercial splits/ducted units. Approx. 14.3 m³/h displacement; POE; R22/R407C.
Reliable rooftop choice with low sound power and ~30.5 kg weight for easy handling.
Suited to higher loads in packaged A/C and multi-zones. Verify envelope and line sizes per datasheet.
Top-end model for heavier commercial duty — confirm stub dimensions and MCC before ordering.
Compliance reminder: Australian refrigerant handling requires licensing and adherence to the current Code of Practice. Check the official guidance before site work.
Ships within 48 hours · Estimated delivery Jun 23 - Jun 28
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order